What was found
INSPECTION TYPE:C2 CARGO PIT C DOOR CORNER CLIPS CRACKED INSIDE LIGHTENING HOLES FS STA 1170 TO 1210 AT LONG 22R APPROX. FOUND DOOR PAN/FRAME CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND INSTALLED CLIPS, DOUBLERS, AND DOOR PAN SECTION IAW DWG 5894025 AND SRM 52-2-0 FIG 2, 52-4-1.