What was found
INSPECTION TYPE:C1 RT WING STR 51 I/B SIDE STA 74 IS CRACKED. REMOVED FITTING IAW DC8 SRM 51-1-20D, LOCATED DRILLED AND DEBURRED NEW FITTING IAW DC8 SRM 51-1-24, INSTALLED FITTING IAW DC8 SRM 51-1-20D, TORQUED BOLT IAW DC8 SRM 51-1-23.