What was found
INSPECTION TYPE:C1 L1 LWR FWD DOOR JAMB CORNER CRACKED AT FASTENER HOLE. INTERNAL DOUBLER CRACKED PER X-RAY INSP FOUND OX AND DOUBLE DRILLED HOLES, INSTALLED BUSHINGS IAW DAC DWG 47099818, FABBED REPAIR BUSHINGS IAW DAC DWG 4709987B, BLENDED GOUGES WITHIN LIMITS IAW DC8 SRM 553-2-0. ALODINED, PRIMED & INSTALLED DOUBLERS IAW 53-2-0 FIG 15.