What was found
INSPECTION TYPE:C1 FRAME STA 55 CRACKED AT SUPPORT ROD ATTACH FITTING LONG 24R. CUT OUT DAMAGED FRAME IAW SRM 53-2-0 FIG 2. FABRICATED FRAME AND ANGLE REPAIR IAW SRM 53-2-0 FIG2, INSTALLED FRAME ANGLE DOUBLER IAW SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 FRAME STA 55 CRACKED AT SUPPORT ROD ATTACH FITTING LONG 24R. CUT OUT DAMAGED FRAME IAW SRM 53-2-0 FIG 2. FABRICATED FRAME AND ANGLE REPAIR IAW SRM 53-2-0 FIG2, INSTALLED FRAME ANGLE DOUBLER IAW SRM 51-1-20D.