What was found
INSPECTION TYPE:C-1 C-BAG BIN, BATHTUB FITTING CRACKED AT STA 1200, LONG-28L. REMOVED BATH TUB FITTING, FABRICATED REPAIR DOUBLER IAW SRM 53-2-0 FIG 2D. INSTALLED REPAIR DOUBLER INSTALLED NEW FITTING IAW SRM 53-2-0 FIG2D, AND SRM 51-1-20D.