What was found
INSPECTION TYPE: C1, FUSELAGE AT STA 1745 ABOVE LONGERON 15 RT, SKIN CRACKED. PERFORMED HFEC IAW DAC SPM NDT MANUAL PT 6 51-00-01.003 TO VERIFY CRACK REMOVED DAMAGED AREA, FABRICATED REPAIR DOUBLER, FINGER DOUBLERS AND FILLER IAW DC8 SRM 53-2-1 FIG 7 ALODINED AND PRIMED REPAIR PART S IAW DC8 SRM 51-1-8. INSTALLED REPAIR PARTS IAW DC8 SRM 53-2-1 FIG 7, 51-1-21, AND 51-1-20D