What was found
INSPECTION TYPE: C2, C-PIT DOOR HAS A CRACKED INTERCOSTAL ABOVE LOWER DOOR HOOK AT STA. 1176 AT LONG. 32R AREA ON DOOR. CUTOUT CRACKED INTERCOSTAL, FABRICATED INTERCOSTAL SECTION, AND DOUBLER I.A.W. SRM. 52-2-0 FIG. 2
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C2, C-PIT DOOR HAS A CRACKED INTERCOSTAL ABOVE LOWER DOOR HOOK AT STA. 1176 AT LONG. 32R AREA ON DOOR. CUTOUT CRACKED INTERCOSTAL, FABRICATED INTERCOSTAL SECTION, AND DOUBLER I.A.W. SRM. 52-2-0 FIG. 2