What was found
INSPECTION TYPE: C2, SEVERAL STRESS FASTENERS AT STA. 1660 LONG. 31 RT. OPENED SKIN FOUND FILLER CORRODED BEYOND LIMITS, FABRICATED AND REPLACED FILLER IAW DWG. 5773311,AND CLOSED SKIN I.A.W. SRM. 51-1-21,51-1-20D
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C2, SEVERAL STRESS FASTENERS AT STA. 1660 LONG. 31 RT. OPENED SKIN FOUND FILLER CORRODED BEYOND LIMITS, FABRICATED AND REPLACED FILLER IAW DWG. 5773311,AND CLOSED SKIN I.A.W. SRM. 51-1-21,51-1-20D