What was found
INSPECTION TYPE:C-2 FWD CARGO PIT ATTACH FITTING FOR MAIN CABIN FLOORBOARD CRACKED ON FWD SIDE OF FLOORBEAM STA 160 BL 0. FABRICATED ONE FITTING IAW DC8 DWG 4772359, LOCATED HOLES AND INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-2 FWD CARGO PIT ATTACH FITTING FOR MAIN CABIN FLOORBOARD CRACKED ON FWD SIDE OF FLOORBEAM STA 160 BL 0. FABRICATED ONE FITTING IAW DC8 DWG 4772359, LOCATED HOLES AND INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D.