What was found
INSPECTION TYPE:C, AFT CARGO CORROSION ON FLOORBEAM UPPER CHORD AT STA 1902 0-20 RBL. CORROSION TRIMMED OUT IAW SRM 53-00-01 FIG 9. HFEC INSPECTION CARRIED OUT, NO CRACKS FOUND ON TRIMMED AREA. REPAIR ANGLE & FILLER, FAB & INSTALLED IAW SRM 53-00-01 VOL I & VOL II.