As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C, AFT CARGO BILGE AREA FRAME SHEAR TIE FOUND WITH CORROSION AT STA 1953 LONG 51 RT - 52 RT. CORROSION FOUND EXCEEDING LIMIT ON SHEAR TIE AT STA 1953 LONG 51 RT - 52 RT AS PER SRM 53-00-01 VOL I REV 31. SHEAR TIE & SURROUNDING PARTS REMOVED IAW SRM 51-35-01 VOL II & 51-33-01 VOL II. NEW SHEAR TIE FABRICATED AND INSTALLED AS PER DWG AGA7133.