What was found
INSPECTION TYPE:C, CENTER CARGO PANEL SUPPORT STRUCTURE AT STA 1841, LBL 30 TO RBL 30 CORRODED. SUPPORT REMOVED AT STA 1841 IAW SRM 51-35-01 VOL II REV 31. NEW SUPPORT INSTALLED IAW SRM 51-35-01 VOL II REV 31.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, CENTER CARGO PANEL SUPPORT STRUCTURE AT STA 1841, LBL 30 TO RBL 30 CORRODED. SUPPORT REMOVED AT STA 1841 IAW SRM 51-35-01 VOL II REV 31. NEW SUPPORT INSTALLED IAW SRM 51-35-01 VOL II REV 31.