What was found
INSPECTION TYPE:C&SI R/H W/W BS 930 HORIZ. INTERCOSTAL COMMON TO BS 930 FRAME EVIDENCE OF CORROSION ON HORIZ. AND VERTICAL FLANGE REPAIR CARRIED OUT IAW SMRO EO 2003-003-013 UPS ENGINEERING FILE NO. 727-53-20093
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C&SI R/H W/W BS 930 HORIZ. INTERCOSTAL COMMON TO BS 930 FRAME EVIDENCE OF CORROSION ON HORIZ. AND VERTICAL FLANGE REPAIR CARRIED OUT IAW SMRO EO 2003-003-013 UPS ENGINEERING FILE NO. 727-53-20093