What was found
INSPECTION TYPE: C&SI, SUSPECT CRACK ON FRAME ADJACENT TO HINGE STRUCTURE AT FWD END OF FWD CARGO BAY DOOR. ON REMOVAL OF STIFFENER IN PREPARATION FOR REPAIR A NEW CRACK WAS FO UND WHICH WAS OUTSIDE THE PERMITED REPAIR AREA. FRAME WAS REMOVED IAW SRM 51-30-02. FRAME FABRICATED IAW SRM 51-30-02 FRAME INSTALLED IA W SRM 51-30-02. REPAIR CARRIED OUT IAW SRM 51-10-1