INSPECTION TYPE: C, VERTICAL FIN LEADING EDGE LOWER PANEL 9501, MATING STRAP HAS A CRACK IN THE OUTER SKIN. CRACK STOP DRILLED IAW SRM 51-10-01, REPAIR DOUBLER FABRICATED IAW SRM 51-20-01, FIG 7. REPAIR DOUBLER INSTALLED IAW SRM 51-30-02.