What was found
INSPECTION TYPE: C, FOLLOWING X-RAY INSPECTION OF RT ELEVATOR TAB, WATER INGRESS FOUND ON RT ELEVATOR TAB AT APPROX ELEV STA 95 TO ELEV STA 105. REPAIR CARRIED OUT IAW SRM 51-40-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, FOLLOWING X-RAY INSPECTION OF RT ELEVATOR TAB, WATER INGRESS FOUND ON RT ELEVATOR TAB AT APPROX ELEV STA 95 TO ELEV STA 105. REPAIR CARRIED OUT IAW SRM 51-40-05.