What was found
INSPECTION TYPE: C M/D - AFTER FLOOR PANEL REMOVED, FLOOR SUPPORT FOUND CORROSION AT BS 2280-2300 LBL 60. FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 8. DEPTH 0.035 INCH, WIDTH 1 INCH, LENGTH 3 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C M/D - AFTER FLOOR PANEL REMOVED, FLOOR SUPPORT FOUND CORROSION AT BS 2280-2300 LBL 60. FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 8. DEPTH 0.035 INCH, WIDTH 1 INCH, LENGTH 3 INCHES.