What was found
INSPECTION TYPE: C, LEFT WING - NR 3 FLAP TRACK AFTER END INNER SURFACE I/B WALL AREA FOUND CORROSION (FINDING AFTER PIVOT FITTING REMOVAL). LEFT WING NR 3 FLAP TRACK AFT END INNER SURFACE INBD WALL AREA CORROSION REMOVED AND REPROTECTED REFER CWS SERIAL NR 016250, 016850 TO 16854 FOR WORK DETAILS. REF HX RS 57-53-34971 AND EO B747-5740-18331 -A. BLEND AREA 1.5 X 1.5 INCH, THICKNESS REMAIN 0.124 INCH AND ORIGINAL THICKNESS 0.207 INCH.