What was found
INSPECTION TYPE: PFLT, 3 INCH CRACK IN WEB AFT FRAME UPPER SIDE, MARKED. REMOVED FRAME WEB AT STA 488 FROM APPROX 5-16 TO 5-22. STARTED FABRICATION OF REPLACEMENT WEB AND TWO SPLICE PLACE IAW SRM 53-10-04. COMPLETED FABRICATING OF WEB & (2) SPLICE PLATES. TREATED, PRIME, PAINTED & STARTED TO INSTALL REF SRM 53-10-4 ON LWR SPLICE PLATE. COMPLETED THE EO FOR SHORT FASTENER EDGE DISTANCE. COMPLETED REPAIR.