As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRICAL FUMES IN COCKPIT. FOUND R-1 WINDOW WIRE HOT. WIRE AND POST SO HOT YOU COULD NOT TOUCH THEM. FOUND D404 TERMINAL ARCING AND IT HAD DAMAGED TERMINAL SO IT COULD NOT BE REPAIRED. REMOVED AND REPLACED WINDOW. LT WINDOW HEAT CONTROLLER REMOVED AND REPLACED PER MM 30/41/01. REMOVED AND REPLACED R-1 WINDOW IAW MM 56-11-1. OK FOR SERVICE,