What was found
INSPECTION TYPE:N/A M/D - BS 760 LBL 40 FLOORBEAM UPPER SURFACE FOUND CORRODED. FLOORBEAM REPAIRED PER SRM 51-40-04 FIG 3. CORROSION BLEND OUT 0.060 X 2 X 2 INCHES, EXCEED SRM LIMIT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:N/A M/D - BS 760 LBL 40 FLOORBEAM UPPER SURFACE FOUND CORRODED. FLOORBEAM REPAIRED PER SRM 51-40-04 FIG 3. CORROSION BLEND OUT 0.060 X 2 X 2 INCHES, EXCEED SRM LIMIT.