What was found
INSPECTION TYPE: C, KEELBEAM PANEL SUPPORT BRACKET FOUND SURFACE CORROSION AT STA 1095 LBL 9. CORROSION BLEND OUT (0.040 X 1 X 1 INCHES) SUPPORT BRACKET REPLACED AS PER SRM 51-10-01 P.8
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, KEELBEAM PANEL SUPPORT BRACKET FOUND SURFACE CORROSION AT STA 1095 LBL 9. CORROSION BLEND OUT (0.040 X 1 X 1 INCHES) SUPPORT BRACKET REPLACED AS PER SRM 51-10-01 P.8