What was found
INSPECTION TYPE: C, KEELBEAM PANEL SUPPORT SURFACE FOUND SURFACE CORROSION AT STA 1276 TO STA 1287 RBL 16. CORROSION BLEND OUT (0.020 X 1 X 1). KEEL BEAM PNL SUPPORT REPLACED AS PER SRM 51-10-01 P.8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, KEELBEAM PANEL SUPPORT SURFACE FOUND SURFACE CORROSION AT STA 1276 TO STA 1287 RBL 16. CORROSION BLEND OUT (0.020 X 1 X 1). KEEL BEAM PNL SUPPORT REPLACED AS PER SRM 51-10-01 P.8.