INSPECTION TYPE: C, M/D - L5 DOOR T/T LWR HINGE LWR BEARING ASSY MOUNTING SUPPORT AREA CORROSION. CORROSION BLEND OUT (0.040 X 1 X 1 INCH). M/D L5 DOOR LWR HINGE LWR SUPPORT WEB REPLACED AS PER SRM 51-10-01 PG 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, M/D - L5 DOOR T/T LWR HINGE LWR BEARING ASSY MOUNTING SUPPORT AREA CORROSION. CORROSION BLEND OUT (0.040 X 1 X 1 INCH). M/D L5 DOOR LWR HINGE LWR SUPPORT WEB REPLACED AS PER SRM 51-10-01 PG 8.