What was found
INSPECTION TYPE: C FX - STA 240 LBL 28, M/D FLOOR SUPPORT BEAM WEB FOUND CRACKED AS MARKED. FX - STA 240 M/D FLOOR SUPPORT BEAM WEB REPAIRED IAW SRM 53-10-07 FIG 11 JUST BETWEEN LBL 18 INCHES TO LBL 38 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C FX - STA 240 LBL 28, M/D FLOOR SUPPORT BEAM WEB FOUND CRACKED AS MARKED. FX - STA 240 M/D FLOOR SUPPORT BEAM WEB REPAIRED IAW SRM 53-10-07 FIG 11 JUST BETWEEN LBL 18 INCHES TO LBL 38 INCHES.