What was found
INSPECTION TYPE: C, FX - BODY FAIRING SUPPORT FRAME FOUND SURFACE CORROSION AT STA 920 FROM RBL 20 - 50. CORROSION BLEND OUT 0.056 X 1 X 1.5 INCH. BODY FAIRING SUPPORT FRAME REPAIRED AS PER SRM 53-50-04 FIG 2 AT STA 920 FROM RBL 0 - RBL 30 AREA. BODY FAIRING SUPPORT CORROSION AREA STA 920 RBL 30 - RBL 50 CORROSION CLEANED AND REPROTECTED AS PER SRM 51-10-01 AND SRM 51-10-02 WITHIN SRM 53-50-01 FIG 5 LIMIT.