What was found
INSPECTION TYPE: C, FX - BODY FAIRING SUPPORT FOUND SURFACE CORR AT STA 920 FROM LBL 30 - RBL 20. BODY FRG SUPPORTT COR REMOVED AT LBL 25 TO LBL 30 AND REPROTECTED AS PER SRM 51-10-01 AND 51-10-02 WITHIN SRM 53-50-01 FIG 5 LIMITATION, BL 0 TO LBL 26 SUPPORT REPAIRED AS PER SRM 53-50-04 FIG 2 DUE TO EXCEEDED LIMITATION AS PER SRM 53-50-01 FIG 5 AFTER COR BLEND OUT 0.050 X 1 X 1 INCH BL 0 TO RBL 20 SUPPORTT REPAIRED REF NRC 5856 DETAIL.