What was found
DENT AT NOSE ACFT JACK PAD MOUNT PROTRUDING OUTWARD POSSIBLE CORROSION FMS STA 405 STRINGER 38RT. USED LFEC INSP OF AREA. INDICATION OF APPX 20 PERCENT MATERIAL LOSS. QC 10445/ (2) DEMENTIONS OF DENT IS .045 IN DEPTH. 75705/ THE DAMAGE ALLOWED REF EO. B747-5330-19344A. FOR FIFTY FLT HRS. REF D268037. SMOOTHED OUT AS PER SRM 51-10-01 AND 51-10-02. DEPTH 0.003, WIDTH 2 INCHES, LENGTH 3 INCH WITHIN SRM 53-30-01 FIG 1 LIMIT. HFEC INSP C/OUT PER NTM PART 6 51-00-00 FIG 4 AND NO CRACK FOUND. DMI 268037 (CLOSED)