What was found
INSPECTION TYPE: C-2, AFT PIT DOOR SLIDE AREA STA 1210 BETWEEN LONG 31R-32R END FITTING CORRODED. REMOVED EXISTING FITTINGS, LOCATED, DRILLED AND DEBURRED NEW FITTINGS P/N 3754930-1N, 5894282-501, & 5894282-502 IAW DC8 SRM 51-3-2 AND INSTALLED FITTINGS IAW DC8 SRM 51-1-20D.