What was found
INSPECTION TYPE: C3, AFT CARGO PIT AT FS 1210 BETWEEN L33R-34R T-BOLT LATCH BACKUP FITTING IS CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8. OUT OF LIMITS IAW DC8 SRM 53-2 -0. LOCATED, TRIMMED AND DRILLED UP FITTING 3754930-1 AND REPAIR FITTINGS 5894282-501, 5894282-502, IAW DC8 SRM 53-2-0. INSTALLED FITTING AND REPAIR FITTING IAW DC8 SRM 53-2-0, 51-1-20D.