What was found
INSPECTION TYPE: C3, LEFT WING FLAP HINGE SUPPORT FITTING AT STA XF 339 7332 CRACKED AT OUTBOARD SIDE JUST FWD OF FLAP FWD SPAR. REMOVED BASE FITTING, CENTER FITTING, SLIDER PANEL, OUTBOARD TRACK, CLOSURE PANELS AND SPRING PANEL IAW DC8 SRM 51-3-0. LOC AND DRILLED BASE FITTING AND CENTER FITTING IAW DAC DWG 5751174. ALODINED AND PRIMED FITTINGS IAW DC8 SRM 51-1-8. INSTALLED BASE FITTINGS AND CENTER FITTINGS IAW DAC DWG 5751174. RE-INSTALLED PANELS AND OUTBOARD SLIDER TRACK IAW DC8 SRM 51-3-0.