What was found
INSPECTION TYPE: C-1, LONGERON SPLICE FITTING CRACKED AT LONGERON 12L BETWEEN STA 300-320. REMOVED, FABRICATED AND REPLACED LONGERON SPLICE FITTING IAW SAA SK 811-748, UPS ENGINEERING FILE NUMBER DC8-53-20283, DWG 4613574 SRM 51-1-20D.