What was found
INSPECTION TYPE: C3, PERFORM LT WING AND RT WING FWD SPAR INSPECTION OF LWR SPAR CAP PER EO DC8-5 710-14184-C AS REQUIRED. REAMED 1 DISCREPANT HOLE ON L/W TO .3230, PERFORMED HFEC AND NO CRACKS NOTED PER DAC SPM 06-10-01.003. CHECKED SPAR THICKNESS AT .689 & L/E SKIN AT .143. FAB'D BUSHINGS FOR REPAIR IAW DAC DWG 4709980 & SRM 51-1-25. REAMED HOLE TO PRE COIN SIZE AND STRESS COINED PER DPS 3.67-56. INSTALLED BUSHINGS PER SRM 51-1-23.