What was found
INSPECTION TYPE: C3, APPROX. STA 700, LONG 35 RT, SHEAR TIE (FRAME ANGLE) UNDER STRESS PN L IS CORRODED AND CRACKED REMOVED DAMAGED SECTION OF SHEAR TIE IAW DC8 SRM 51-1-20D, FABBED NE W SECTION IAW DWG 9753780, LOCATED AND DRILLED UP NEW SECTION IAW D WG 9753780 ALODINED AND PRIMED IAW DC8 SRM 51-1-8 AND INSTALLED ON AIRCRAFT IAW DC8 SRM 51-1-20D