What was found
INSPECTION TYPE: C1, STATION 1700 LONGERON 11L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG. 4772397 AND SRM. 51-1-20D
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1, STATION 1700 LONGERON 11L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG. 4772397 AND SRM. 51-1-20D