What was found
INSPECTION TYPE: C1, STATION 1153 AT LONGERON 19R INSIDE HOLE HAS A CRACKED STRINGER CLIP. REMOVED AND REPLACED CLIP IAW DWG. 4750419 AND SRM. 51-1-20D
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1, STATION 1153 AT LONGERON 19R INSIDE HOLE HAS A CRACKED STRINGER CLIP. REMOVED AND REPLACED CLIP IAW DWG. 4750419 AND SRM. 51-1-20D