What was found
INSPECTION TYPE: C1, HFEC INSP. OF L-1 DOOR FWD. UPPER CORNER DETECTED A CRACK COMING FROM THE EDGE OF THE CUTOUT EXTENDING FWD AND UP APPROX. 2.375 INCHES AT STA. 25 LONG. 10L REMOVED EXISTING REPAIR, CUTOUT DAMAGED AREA, NDT VERIFIED NO CRACKS AT CUTOUT, FABRICATED AND INSTALLED DOUBLER,TRIPLER, AND FILLER IAW SRM. 53-2-0 FIG. 15 AND SAA SK 808-031