What was found
INSPECTION TYPE: C-2, FWD PIT STA 320 LBL 27 FLOORBOARD, TRACK CORRODED. REMOVED CORROSION, WITHIN LIMITS IAW DC8 SRM 53-2-3. FOUND SCALLOP ON UPPER SURFACE WORN BEYOND LIMITS IAW DC8 SRM 53-2-3. REMOVED AND REPLACED TRACK SECTION IAW DC8 SRM 51-3-0, 53-2-3 FIG 14 AND UPS DWG 53B-0 03. ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED UPS SPLICE DC8- 53B-003-501 IAW UPS DWG DC8-53B-003.