What was found
INSPECTION TYPE: C2, CENTER FLOOR TRACK BL 0 STA 1190 IS EXCESSIVELY WORN. BLENDED FLOOR TRACK (ORIG .420, REM .550) OUT OF LIMITS IAW DC8 SRM 53-2-3. REMOVED DAMAGED FLOOR TRACK, LOCATED, DRILLED & DEBURRED NEW SEAT TRACK 60-15176 IAW DC8 SRM 53-2-3. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED SEAT TRACK IAW DC8 SRM 53-2-3/51-3-0.