What was found
INSPECTION TYPE: C1, AFT CARGO PIT AT FS 1140-1150 BETWEEN L32R-L33R INTERCOSTAL ATTACK F ITTING IS CRACKED VERIFIED CRACK IAW DYE PENETRANT TEST IAW DPS 4.707.1. REMOVED CRACKED FITTING IAW DC8 SRM 51-1-20D. REC'D, LOCATED, AND DRILLED NEW FIT TING IAW DC8 SRM 51-1-24 AND INSTALLED IAW DC8 SRM 51-1-20D