What was found
INSPECTION TYPE: C1, AFT CARGO PIT AT FS 1140-1150 L35L INTERCOSTAL ATTACH FITTING IS CRACKED. VERIFIED CRACK IAW DYE PENETRANT TEST IAW DPS 4.707.1, REMOVED FITTIN G IAW DC8 SRM 51-1-20D, RECEIVED NEW FITTING P/N 3758497.1N PO NR 3541 22 LOCATED AND DRILLED IAW DC8 SRM 51-1-20D, AND INSTALLED IAW DC8 S RM 51-1-20D