As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: C1, RT FWD TYPE 1 DOOR HAS A CRACKED FITTING BELOW THE MOST FORWARD LOWER ST OP FITTING AT AFT FRAME OF THE FORWARD WEB SECTION REMOVED FITTING RT EMERGENCY EXIT DOOR LOWER CORNER. REMOVED RT EMERGENCY EXIT DOOR. LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-3-2 INSTALLED FITTING IAW DC8 SRM 51-1-20D, 51-1-21, 51-3-0.