What was found
INSPECTION TYPE: C2, LONG. 32L SPLICE FITTING IS CRACKED AT STA. 610. REMOVED, FABRICATED AND REPLACED FITTING I.A.W. DWG. 3750330,AND SRM. 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C2, LONG. 32L SPLICE FITTING IS CRACKED AT STA. 610. REMOVED, FABRICATED AND REPLACED FITTING I.A.W. DWG. 3750330,AND SRM. 51-1-20D.