What was found
INSPECTION TYPE: C3, AFT PIT AT STA 1220 STR 34R INSIDE TORQUE BOX AREA FITTING CRACKED. REMOVED FITTING CRACKED IAW DC8 SRM 51-1-20D, REC'D NEW Z-FITTING AND 2 EA PLATES P/N 3755841-1, P/N 3755841-3, P/N 3755841-5. LOCATED, DRILLED, AND TRIMMING IAW DC8 SRM 53-2-0, AND 51-1-20D. INSTALLED Z-FITTING AND PLATES IAW DC8 SRM 51-1-20D.