What was found
INSPECTION TYPE: C3, AT FUSELAGE STA 700 (APPROX) INSIDE STRESS PANEL AREA, SHEAR TIE ON LT SIDE CRACKED. FABRICATED SHEAR TIE FROM MAT 7075-0.071 AND HEAT TREATED TO T-6 IAW DAC DWG 5750365 & TPS 1003 REV A FOR HEAT TREAT. LOCATED, DRILLED, AND DEBURRED IAW DC8 SRM 51-1-24, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-20D.