What was found
INSPECTION TYPE: C3, AIR CONDITIONING ACCY COMPARTMENT AT STA 46 RBL 44. FLOORBEAM MISSING TWO FASTENERS. UPON INSP OF MISSING FAST FOUND FLOORBEAM TO BE CORRODED, REMOVED CORRODED IAW DC8 SRM 51-1-8 OUT OF LIMITS IAW DC8 SRM 53-2-0, REMOVED FLOORBOARD AN D 2 EA FLOOR SUPPORT ANGLES. FABBED TEE CAP REPAIR ANGLE IAW TR 53-152 AND FLR SUPPORT ANGLE IAW DAC DWG 4774654. ALODINED, PRIMED AND INSTALLED IAW DC8 SRM 51-1-8, 51-1-20D, 51-3-0, AND TR 53-152 FIG 1H.