What was found
INSPECTION TYPE: C, RT WING, UPPER SURFACE, FWD O/B FLAP FIXED PANEL STA XORS=799 FOUND CORROSION. CORROSION REMOVED AND PROTECTED AT REAR SPAR UPPER CAP AFT LEG FROM ST A XORS 780 TO STA 826 PER SRM 51-21-01 REV 32 VOL II. MATERIAL REMOVED 0.025 INCH, ORIGINAL THK 0.262 INCH, LEAVE THE BLENDOUT AREA 'AS IS' PER EN1014-03 AND UPS REPAIR/ALTERATION AUTH. ENGINEERING FILE NUMBER : MD11-57-20010. 2. HFEC INSP C/OUT ON REWORK AREA, NO CRACK FOUND.