Service difficulty report · Connector · Airbus A300F4622R

Difficulty date
March 4, 2004
Submitted
March 10, 2004
Operation
Air carrier
Aircraft
N142UP
Make and model
Airbus A300F4622R
Aircraft serial
0825
Part
Connector
Condition
Loose
Location
Escape Slide
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RED LIGHT ON EMERGENCY ESCAPE SLIDE TEST WILL NOT ILLUMINATE, BUZZER OPERATES NORMALLY. DEFERRED EVAC SLIDE WARNING LIGHT PER A300 MEL 52-73-01-1. PLACARD INSTALLED. CLOSING LP 146228 - RESET CONNECTOR ON AUTONOUMOUS POWER SUPPLY UNIT. OPS CK NORMAL, MEL 277035 CLEARED.