What was found
INSPECTION TYPE: C, INTERGRANULAR CORROSION FOUND ON CEILING PANEL BRACKET AT BS 1130 AFT CARGO COMPT, AS MARKED. HFEC INSPECTION CARRIED OUT AROUND CUTOUT AT THE ABOVE AREA IAW B727 NDTM PT 6 51-00-00 NDF. REPAIR CARRIED OUT IAW SRM 51-40-04.