What was found
INSPECTION TYPE:C, INSPECT CRACK ON BS 1183 BULKHEAD, SUSPECT CRACK IS LOCATED ON AFT SIDE OF BULKHEAD, WL 175 APPROX LBL 20. HFEC INSPECTION CARRIED OUT & CRACKS CONFIRMED AND ENDS MARKED. FASTENERS REMOVED AND CRACKS TRIMMED OUT IAW SRM 51-10-6, REPAIR CARRIED OUT IAW AAAE EO 2004-068-003 R1.